Utilization: measurement of characteristics of motors and load, as well as simulation of load.

Description: a measurement station enables operational analyses of electrical drives. The station consists of various types of driving machines and active load, which replaces real load.

Basic data:

Driving machines:

  • a DC motor of 3.3 kW power supplied with SIMOREG DC MASTER;
  • an asynhrounous motor of 4.0 kW power supplied with SIMOVERT VC;
  • an asynhrounous motor with three shifts of speed, with power 0.75/0.65/0.55 kW;
  • an asynhrounous motor of 3.0 kW with thyristor's power supply for soft startup.

Active load: an asynhrounous motor of 5.5 kW powered with a frequency converter and controlled with a program, which enables input of various load's momentum caharacteristics.

Utilization: power supply of one-phase and three-phases measured objects with various forms of voltage and frequency.

Basic data:

  • AC or DC voltage;
  • current ranges: range 1. 3 x 0-156 VRMS, 13A; range 2. 3 x 3 0-312 VRMS, 6.5A;
  • power output: 3 x 1750 VA;
  • frequency: DC, 40-5000 Hz.

Links:

Utilization: power supply of measured objects with higher frequency voltage.

Basic data:

  • a frequency range: 20 kHz do 3 MHz;
  • power output: 2000 W.

Links:

Utilization: magnetization of rare earthy (NdFeB, SmCO) and other hardmagnetic materials.

Basic data:

  • maximum voltage: 2000 V;
  • nominal peak current: 60 kA;
  • capacity: 1.25 mF;
  • impulse energy: 2.5 kJ.

Links:

Utilization: measurement of voltage, current, power, a work factor and other parameters in one-phase and three-phases systems.

Basic data:

  • voltage ranges: 0.3, 1, 3, 10, 30, 100, 300 and 1000 V;
  • current ranges: 0.06, 0.2, 0.6, 2, 6 and 20 A;
  • a frequency range: DC up to 3 MHz.

Links:

Utilization: measurement of load of rotating machines.

Basic data:

  • a maximum number of revolutions: 25 000 rev/min;
  • maximum moment: 280 mNm;
  • power: 50 W (250 W maximum 5 min).

LInks:

Utilization: measurement of load of rotating machines.

Basic data:

  • a maximum number of revolutions: 50000 rev/min;
  • maximum moment: 3 Nm;
  • power: 3 kW @ 9550 rev/min.

Links:

Utilization: measurement of characteristics of rotating machines.

Basic data:

  • control of revolutions or moment;
  • an analogous output of revolutions or moment;
  • interfaces RS-232 and IEEE-488;
  • a programable digital PID value.

Links:

Utilization: measurement of density of magnetic flux and intensity of a magnetic field in space.

Basic data:

  • measurement ranges B: 30 and 300μT, 3, 30, and 300mT, 3T;
  • measurement ranges H: 24 and 240 A/m, 2.4, 24 and 240 kA/m, 2.4 MA/m;
  • a frequency range: DC, AC od 20 Hz do 20 kHz;
  • an interface: RS-232;
  • a measurement probe: axial HS AGB5-4805 and transversal HS TGB5-104005.

Links:

Utilization: measurement of magnetic flux within material and space.

Basic data:

  • measurement ranges Φ: 2E-4, 2E-3, 2E-2 and 2E-1 Vs;
  • an interface: analogous output.

Links:

Utilization: measurement of temporal flux of electrical signals.

Basic data:

  • measurement ranges B: 30 and 300μT, 3, 30, and 300mT, 3T;
  • measurement ranges H: 24 and 240 A/m, 2.4, 24 and 240 kA/m, 2.4 MA/m;
  • frequency: 100 MHz;
  • a number of channels: 4;
  • sampling speed in real time: 2.5 GS/s;
  • maksimum memory: 5 M;
  • connectivity: USB Host, USB Device, LAN(10/100-Base-T Ethernet), Video Out;
  • mathematical operations: arithmetics, FFT, advance mathematics, an analysis of supplied voltage.

Links:

Utilization: measurement of an electromagnetic field in environment.

Basic data:

  • measurement ranges B: 30 and 300μT, 3, 30, and 300mT, 3T;
  • measurement ranges H: 24 and 240 A/m, 2.4, 24 and 240 kA/m, 2.4 MA/m;
  • a fequency range: from 10 kHz to 7 GHz;
  • demodulation: AM/FM/SSB;
  • an interface: Ethernet 10/100 Base T; USB 2.0.

Links:

  • Gaussmeter FH 3;
  • a magnetic normal;
  • single plate measurement devices;
  • a round shape rotational single plate measurement device;
  • a rectangular shape rotational single plate measurement device;
  • measurement load for half-hard and hard magnetic materials;
  • Epstein's load;
  • programable precission multimeter DM 5120;
  • digital oscilloscope Tektronix 11401;
  • a measurement device of electromagnetic fieldPMM 8053 in environment;
  • Keithley Picoampermeter 485;
  • a Keithley voltage source with measurement device 2410 1100 V;
  • sound levelmeasurement device UNITEST 93516;
  • Anemometer UNITEST 93460;
  • Isolation tester NORMA;
  • power amplifier JBL MPX 1200;
  • a programable RLC meter;
  • a flexible current sensor;
  • an AC/DC current probe;
  • a voltage difference probe;
  • a highvoltage difference probe;
  • measurement shaft 8645 (75 Nm) ;
  • a hardness measurement device (Equotip Piccolo Hardness Tester) ;
  • an infrared termometer;
  • a temperature calibrator (Fluke 9140) ;
  • four square amplifiers (Tollner 7610-40) ;