Equipment - hardware

Utilization: measurement of characteristics of motors and load, as well as simulation of load.
Description: a measurement station enables operational analyses of electrical drives. The station consists of various types of driving machines and active load, which replaces real load.
Basic data:
Driving machines:
- a DC motor of 3.3 kW power supplied with SIMOREG DC MASTER;
- an asynhrounous motor of 4.0 kW power supplied with SIMOVERT VC;
- an asynhrounous motor with three shifts of speed, with power 0.75/0.65/0.55 kW;
- an asynhrounous motor of 3.0 kW with thyristor's power supply for soft startup.
Active load: an asynhrounous motor of 5.5 kW powered with a frequency converter and controlled with a program, which enables input of various load's momentum caharacteristics.

Utilization: power supply of one-phase and three-phases measured objects with various forms of voltage and frequency.
Basic data:
- AC or DC voltage;
- current ranges: range 1. 3 x 0-156 VRMS, 13A; range 2. 3 x 3 0-312 VRMS, 6.5A;
- power output: 3 x 1750 VA;
- frequency: DC, 40-5000 Hz.
Links:
Utilization: power supply of measured objects with higher frequency voltage.
Basic data:
- a frequency range: 20 kHz do 3 MHz;
- power output: 2000 W.
Links:
Utilization: magnetization of rare earthy (NdFeB, SmCO) and other hardmagnetic materials.
Basic data:
- maximum voltage: 2000 V;
- nominal peak current: 60 kA;
- capacity: 1.25 mF;
- impulse energy: 2.5 kJ.
Links:
Utilization: measurement of voltage, current, power, a work factor and other parameters in one-phase and three-phases systems.
Basic data:
- voltage ranges: 0.3, 1, 3, 10, 30, 100, 300 and 1000 V;
- current ranges: 0.06, 0.2, 0.6, 2, 6 and 20 A;
- a frequency range: DC up to 3 MHz.
Links:
Utilization: measurement of load of rotating machines.
Basic data:
- a maximum number of revolutions: 25 000 rev/min;
- maximum moment: 280 mNm;
- power: 50 W (250 W maximum 5 min).
LInks:
Utilization: measurement of load of rotating machines.
Basic data:
- a maximum number of revolutions: 50000 rev/min;
- maximum moment: 3 Nm;
- power: 3 kW @ 9550 rev/min.
Links:
Utilization: measurement of characteristics of rotating machines.
Basic data:
- control of revolutions or moment;
- an analogous output of revolutions or moment;
- interfaces RS-232 and IEEE-488;
- a programable digital PID value.
Links:
Utilization: measurement of density of magnetic flux and intensity of a magnetic field in space.
Basic data:
- measurement ranges B: 30 and 300μT, 3, 30, and 300mT, 3T;
- measurement ranges H: 24 and 240 A/m, 2.4, 24 and 240 kA/m, 2.4 MA/m;
- a frequency range: DC, AC od 20 Hz do 20 kHz;
- an interface: RS-232;
- a measurement probe: axial HS AGB5-4805 and transversal HS TGB5-104005.
Links:
Utilization: measurement of magnetic flux within material and space.
Basic data:
- measurement ranges Φ: 2E-4, 2E-3, 2E-2 and 2E-1 Vs;
- an interface: analogous output.
Links:
Utilization: measurement of temporal flux of electrical signals.
Basic data:
- measurement ranges B: 30 and 300μT, 3, 30, and 300mT, 3T;
- measurement ranges H: 24 and 240 A/m, 2.4, 24 and 240 kA/m, 2.4 MA/m;
- frequency: 100 MHz;
- a number of channels: 4;
- sampling speed in real time: 2.5 GS/s;
- maksimum memory: 5 M;
- connectivity: USB Host, USB Device, LAN(10/100-Base-T Ethernet), Video Out;
- mathematical operations: arithmetics, FFT, advance mathematics, an analysis of supplied voltage.
Links:
Utilization: measurement of an electromagnetic field in environment.
Basic data:
- measurement ranges B: 30 and 300μT, 3, 30, and 300mT, 3T;
- measurement ranges H: 24 and 240 A/m, 2.4, 24 and 240 kA/m, 2.4 MA/m;
- a fequency range: from 10 kHz to 7 GHz;
- demodulation: AM/FM/SSB;
- an interface: Ethernet 10/100 Base T; USB 2.0.
Links:
- Gaussmeter FH 3;
- a magnetic normal;
- single plate measurement devices;
- a round shape rotational single plate measurement device;
- a rectangular shape rotational single plate measurement device;
- measurement load for half-hard and hard magnetic materials;
- Epstein's load;
- programable precission multimeter DM 5120;
- digital oscilloscope Tektronix 11401;
- a measurement device of electromagnetic fieldPMM 8053 in environment;
- Keithley Picoampermeter 485;
- a Keithley voltage source with measurement device 2410 1100 V;
- sound levelmeasurement device UNITEST 93516;
- Anemometer UNITEST 93460;
- Isolation tester NORMA;
- power amplifier JBL MPX 1200;
- a programable RLC meter;
- a flexible current sensor;
- an AC/DC current probe;
- a voltage difference probe;
- a highvoltage difference probe;
- measurement shaft 8645 (75 Nm) ;
- a hardness measurement device (Equotip Piccolo Hardness Tester) ;
- an infrared termometer;
- a temperature calibrator (Fluke 9140) ;
- four square amplifiers (Tollner 7610-40) ;
- a DC calibrator (Iskra MI 1077).